The AC resistance-inductive capacitive load is designed according to RLC load part in IEC 62116-2008 Test Method for Islanding Protection Measures of Grid-connected PV Inverter; Sectional combined control is adopted to support sudden loading/unloading; Self-developed power module is used for the resistance part, with high power density, strong heat resistance and forced air cooling to ensure continuous operation of load; High silicon quality oriented silicon steel sheet shall be adopted for inductive load reactor; All insulating materials and electromagnetic conductors shall be of F/H grade, and shall be manufactured in accordance with national standards, with small loss, main insulation, good heat dissipation, corrosion resistance, moisture resistance, strong seismic resistance, safety and reliability; Capacitive load capacitor adopts GB/T3667-2005 certified standard container, with small volume, light weight, good electrical performance, small loss, good self-healing (SH) characteristics, pressure explosion-proof device inside, safe use, no change of capacitance impedance power during loading test. AC resistive capacitive load, 7 load combinations, R load/L load/C load/R load/R load/R load/C load/L load, RLC load, which can simulate the user's various test conditions, is an indispensable R&D test equipment for power supply, generator, photovoltaic energy storage inverter and other products.
●Features:
▶ Display function: display voltage, current, power, frequency, electric quantity and other electrical parameters;
▶ Protection function: over-temperature alarm, over-temperature protection, over-voltage protection, over-current protection, automatic load unloading under abnormal conditions, to ensure equipment and personal safety;
▶ Core power module: self-developed power module, self-developed, high power density, strong heat resistance, low temperature drift, no red heat phenomenon, long service life;
▶ Optional control mode: manual control or touch screen control;
▶ Load accuracy: ± 5%;
▶ Heat dissipation mode: forced air cooling heat dissipation is adopted for load, and small axial flow fan is adopted, with large air volume and low noise, so as to ensure continuous and stable operation of load;
▶ Reference standard: it is designed according to the anti-islanding test load standard in IEC 62116-2008 Test Method for Islanding Protection Measures of Grid-connected PV Inverter.
●Specification and model :